Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Pers Med ; 12(10)2022 Oct 14.
Article in English | MEDLINE | ID: covidwho-2084790

ABSTRACT

This study sought to determine whether the C-MAC video laryngoscope (VL) performed better than a direct laryngoscope (DL) when attempting endotracheal intubation (ETI) in the emergency department (ED) while wearing personal protective equipment (PPE). This was a retrospective single-center observational study conducted in an academic ED between February 2020 and March 2022. All emergency medical personnel who participated in any ETI procedure were required to wear PPE. The patients were divided into the C-MAC VL group and the DL group based on the device used during the first ETI attempt. The primary outcome measure was the first-pass success (FPS) rate. A multiple logistic regression was used to determine the factors associated with FPS. Of the 756 eligible patients, 650 were assigned to the C-MAC group and 106 to the DL group. The overall FPS rate was 83.5% (n = 631/756). The C-MAC group had a significantly higher FPS rate than the DL group (85.7% vs. 69.8%, p < 0.001). In the multivariable logistic regression analysis, C-MAC use was significantly associated with an increased FPS rate (adjusted odds ratio, 2.86; 95% confidence interval, 1.69-4.08; p < 0.001). In this study, we found that the FPS rate of ETI was significantly higher when the C-MAC VL was used than when a DL was used by emergency physicians constrained by cumbersome PPE.

2.
Clin Exp Emerg Med ; 9(1): 1-9, 2022 Mar.
Article in English | MEDLINE | ID: covidwho-1771870

ABSTRACT

OBJECTIVE: Coronavirus disease 2019 (COVID-19) has notably altered the emergency department isolation protocol, imposing stricter requirements on probable infectious disease patients that enter the department. This has caused adverse effects, such as an increased rate of leave without being seen (LWBS). This study describes the effect of fever/respiratory symptoms as the main cause of isolation regarding LWBS after the COVID-19 pandemic. METHODS: We retrospectively analyzed emergency department visits before (March to July 2019) and after (March to July 2020) the COVID-19 pandemic. Patients were grouped based on existing fever or respiratory symptoms, with the LWBS rate as the primary outcome. Logistic regression analysis was used to identify the risk factors of LWBS. Logistic regression was performed using interaction terminology (fever/respiratory symptom patient [FRP] × post-COVID-19) to determine the interaction between patients with FRPs and the COVID-19 pandemic period. RESULTS: A total of 60,290 patients were included (34,492 in the pre-COVID-19, and 25,298 in the post-COVID-19 group). The proportion of FRPs decreased significantly after the pandemic (P < 0.001), while the LWBS rate in FRPs significantly increased from 2.8% to 19.2% (P < 0.001). Both FRPs (odds ratio, 1.76; 95% confidence interval, 1.59-1.84 (P < 0.001) and the COVID-19 period (odds ratio, 2.29; 95% confidence interval, 2.15-2.44; P < 0.001) were significantly associated with increased LWBS. Additionally, there was a significant interaction between the incidence of LWBS in FRPs and the COVID-19 pandemic period (P < 0.001). CONCLUSION: The LWBS rate has increased in FRPs after the COVID-19 pandemic; additionally, the effect observed was disproportionate compared with that of nonfever/respiratory symptom patients.

3.
Medicina (Kaunas) ; 58(2)2022 Feb 01.
Article in English | MEDLINE | ID: covidwho-1667240

ABSTRACT

Background and Objectives: Point-of-care ultrasound (POCUS) is a useful tool that helps clinicians properly treat patients in emergency department (ED). This study aimed to evaluate the impact of specific interventions on the use of POCUS in the ED. Materials and Methods: This retrospective study used an interrupted time series analysis to assess how interventions changed the use of POCUS in the emergency department of a tertiary medical institute in South Korea from October 2016 to February 2021. We chose two main interventions-expansion of benefit coverage of the National Health Insurance (NHI) for emergency ultrasound (EUS) and annual ultrasound educational workshops. The primary variable was the EUS rate, defined as the number of EUS scans per 1000 eligible patients per month. We compared the level and slope of EUS rates before and after interventions. Results: A total of 5188 scanned records were included. Before interventions, the EUS rate had increased gradually. After interventions, except for the first workshop, the EUS rate immediately increased significantly (p < 0.05). The difference in the EUS rate according to the expansion of the NHI was estimated to be the largest (p < 0.001). However, the change in slope significantly decreased after the third workshop during the coronavirus disease 2019 pandemic (p = 0.004). The EUS rate increased significantly in the presence of physicians participating in intensive POCUS training (p < 0.001). Conclusion: This study found that expansion of insurance coverage for EUS and ultrasound education led to a significant and immediate increase in the use of POCUS, suggesting that POCUS use can be increased by improving education and insurance benefits.


Subject(s)
COVID-19 , Point-of-Care Systems , Emergency Service, Hospital , Humans , Insurance Benefits , Interrupted Time Series Analysis , Retrospective Studies , SARS-CoV-2 , Ultrasonography
4.
J Korean Med Sci ; 36(28): e209, 2021 Jul 19.
Article in English | MEDLINE | ID: covidwho-1318379

ABSTRACT

BACKGROUND: Ear-loop-type Korean Filter 94 masks (KF94 masks, equivalent to the N95 and FFP2) are broadly used in health care settings in Korea for the coronavirus disease 2019 pandemic. METHODS: A prospective randomized open-label study was designed to identify differences in the fitting performance between mask wearing methods in three different types of KF94 mask with ear loops between January to March 2021. General-fitting involved wearing an ear-loop-type KF94 mask, and tight-fitting involved wearing a mask aided by a clip connecting the ear loops. Each of the 30 participants wore three types of masks according to a randomly assigned order in both methods and performed a total of six quantitative fit tests (QNFTs) according to the occupational safety and health administration protocol. RESULTS: All fit factors (FFs) measured by the QNFT were significantly higher for tight-fitting method with the clip in all KF94 masks (P < 0.001). However, the total FFs were very low, with a median (interquartile range) of 6 (3-23) and 29 (9-116) for general-fitting and tight-fitting, respectively. When wearing tightly, the horizontal 3-fold type mask with adjustable ear-loop length had the highest FF, with a median of 125, and the QNFT pass rate (FF ≥ 100) increased significantly from 4 (13%) to 18 (60%). CONCLUSION: Even with sufficient filter efficiency, ear-loop-type-KF94 masks do not provide adequate protection. However, in relatively low-risk environments, wearing a face-seal adjustable KF94 mask and tight wearing with a clip can improve respiratory protection for healthcare workers. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04794556.


Subject(s)
COVID-19/prevention & control , N95 Respirators , SARS-CoV-2 , Adult , Female , Health Personnel , Humans , Male , Prospective Studies
5.
J Korean Med Sci ; 36(5): e44, 2021 Feb 01.
Article in English | MEDLINE | ID: covidwho-1059691

ABSTRACT

BACKGROUND: Understanding the changes in emergency department (ED) visit patterns during the coronavirus disease 2019 (COVID-19) outbreak is important for effectively operating EDs during the pandemic. We aimed to analyze the changes in pediatric ED visits during the COVID-19 pandemic and examine the relationship between the number of ED visits and the stringency of government social distancing measures. METHODS: This multicenter retrospective study used data of pediatric (age < 18 years) ED visits in Seoul metropolitan area from June 1, 2018, to May 31, 2020. Patient demographics, ED results, and diagnoses were compared during the COVID-19 period and the previous year. To evaluate the effect of the stringency of social distancing measures on the number of ED visits, a Poisson regression model was developed with month, year, and the average monthly Government Response Stringency Index (GRSI) as fixed effects. RESULTS: In total, 190,732 patients were included. The number of pediatric ED visits during the COVID-19 period was 58.1% lower than in the previous year. There were disproportionate decreases in the numbers of ED visits for children in early childhood (66.5%), low-acuity children (55.2-63.8%), those who did not use an ambulance (59.0%), and those visiting the ED for noninjury complaints (64.9%). The proportion of admissions increased from 11.9% to 16.6%. For every 10-point increase in the GRSI, there was a 15.1% decrease in monthly ED visits. CONCLUSION: A striking decrease in pediatric ED visits was observed during the COVID-19 outbreak, the scale which was associated with the stringency of government policies. Changes in the number and characteristics of children visiting the ED should be considered to facilitate the effective operation of EDs during the pandemic.


Subject(s)
COVID-19/epidemiology , Emergency Service, Hospital/organization & administration , Emergency Service, Hospital/statistics & numerical data , Pediatrics/organization & administration , Adolescent , Child , Child, Preschool , Disease Outbreaks , Female , Hospitalization , Humans , Infant , Infant, Newborn , Male , Physical Distancing , Poisson Distribution , Republic of Korea/epidemiology , Retrospective Studies , Seoul/epidemiology , Tertiary Care Centers
SELECTION OF CITATIONS
SEARCH DETAIL